other
منتجات
كاشف الأجسام المضادة CD34 للكيمياء المناعية

كاشف الأجسام المضادة CD34 للكيمياء المناعية

الجسم المضاد IHC - CD34


  • مراقبة إيجابية:

    Placenta
  • التعريب الخلوي:

    Cytoplasm/cell membrane
  • طلب:

    IHC-P
  • الجسم المضاد الثانوي:

    iVision™
  • المواصفات / مل:

    1、3、6、0.2(Concentrated)

Product name

IHC Antibody --CD34


Packing specification

Code Clone

Specifications

AR0478

SD373

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml

AM0045

QBEnd/10

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml


Intended use

For Research use only. CD34 Antibody reagent is intended for use to qualitatively identify CD34 by microscopy in sections of FFPE tissue using immunohistochemical detection system.


Principle

CD34, also known as Cluster of Differentiation 34, is a transmembrane phosphoglycoprotein that is primarily known for being a surface marker for hematopoietic stem cells (HSCs) and progenitor cells. CD34 is a marker of choice for staining blasts in acute myeloid leukemia. In addition, it is expressed by soft tissue tumors, such as solitary fibrous tumor and gastrointestinal stromal tumor. CD34 expression is also found in vascular endothelium. Add the primary antibody to bind the antigen on tissue sections, and then use HRP labeled secondary antibody binding primary antibody to form the secondary antibody-primary antibody-antigen complex. When DAB chromogenic solution is added, HRP reacts with enzyme substrate to produce brown insoluble reaction product, which indirectly indicating the existence of antigen. 


Main components

Immunoglobulin, antibody diluent


Storage

Store at 2~8℃ for 18 months


Sample requirements

FFPE tissues are usually cut into sections as thin as 35μm with a microtome. These sections are then mounted onto glass slides that are coated with a tissue adhesive.


Protocol

1. Sample preparationDeparaffinize the slides in xylene , , Ⅲ for 5 minutesTransfer the slides once through 100%, 100%, 95%, 75% alcohols for 2 minutes respectively. Rinse slides with deionized water for 30 seconds.

2BlockingBlock endogenous peroxidase activity by incubating sections in 3% H2O2 solution at room temperature for 5 minutes to block endogenous peroxidase activity. Rinse the slides with deionized water for 30 seconds.

3Antigen retrievalHeat the EDTA Antigen retrieval buffer to 100. Then place the slides in the boiled buffer and continue to heat for 1520 min. Naturally cool down for 30 minutes. Rinse the sample with wash buffer.

4Primary antibody incubation: Drain the slides. Add primary antibody to tissue, incubate at room temperature for 30 minutes. (use antibody diluent or PBS as control). Wash the slides in PBST for 2 times, 5 minutes for each time. If the Primary antibody is concentrated, please dilute it to RTU(ready to use) according to the information on packing. 

5. Secondary antibody: Drain the slides. Add secondary antibody to tissue and incubate at room temperature for 20 minutes. Wash the slides in PBST for 2 times, 5 minutes for each time.

6. DABDrain the slides. Add DAB to the tissue and incubate at room temperature for 5 min. Rinse slides with deionized water.

7. Hematoxylin stainingDrain the slides. Add Hematoxylin to the tissue and incubate at room temperature for 5 minutes. Rinse slides with water. Use the acid solution for differentiation. Rinse slides with water.

8. DehydrateDehydrate the slides in 75%, 95%, 100% alcohols for 2 minutes. Dry the slides. Cover stained tissue with a coverslip using mounting medium.


Positive localization

1. Positive localization: membrane/cytoplasm.

2. Positive control: tonsil.


Precautions

1. Please read the instruction carefully and become familiar with all components of the kit prior to use, Strictly follow the instruction during operation.

2. DO NOT use the kit or any kit component after their.

3. Only trained professionals can use this kit. Please wear suitable lab coat and disposable gloves while handling the reagents.

4. Avoid contact of skin, eyes and mucous membranes with the chemicals.

5. DO NOT pipet by mouth.

6. Unused reagents, used kit and waste must be disposed according to local regulations.


Manufacturer

Company Name: Xiamen Talent Biomedical Technology Co.,Ltd

Address: No.3rd and 4th Floors , Building B10, No. 2068 Wengjiao Road West, BioMedical Park, Haicang District, Xiamen City, 36100 China

Tel: +86 592 6315755            

البريد الإلكتروني : tlsw@talentbiomedical.com                

الموقع : www.talentbiomedical.com


الرموز


# ترك رسالة
إذا كنت مهتمًا بمنتجاتنا وترغب في معرفة المزيد من التفاصيل ، فالرجاء ترك رسالة هنا ، وسنرد عليك في أقرب وقت ممكن.
يُقدِّم
#
منتجات ذات صله
عرض المزيد

ترك رسالة

ترك رسالة
إذا كنت مهتمًا بمنتجاتنا وترغب في معرفة المزيد من التفاصيل ، فالرجاء ترك رسالة هنا ، وسنرد عليك في أقرب وقت ممكن.

بيت

منتجات

عن

اتصال